Engineering, construction and fabrication
| AWG Wuppertal | ||
| Project description: | Engineering, design and manufacturing of SCR steam pre-heaters for two lines in flue-gas post-cleaning to raise the catalyst operating temperature. | |
| Client: | AWG Wuppertal | |
| Technical data: | Flue gas volume 113,400 kg/h | |
| Receipt of order: | 08/2013 | |
| Status: | Detail engineering | |
| RWE Essen | ||
| Project description: | Modernisation of a steam-gas pre-heater comprising a housing made of carbon steel with TFM foil lining and a heat exchanger bundle of tubes of carbon steel with PFA coating. | |
| Client: | Karnap WtE plant | |
| Technical data: | Clean gas volume 168,000 Nm³/h Heating from 87°C to 140°C | |
| Receipt of order: | 08/2013 | |
| Status: | start of production | |
| DSM Nutritional Products, Switzerland | ||
| Project description: | Engineering, design, manufacturing, assembly and commissioning of a heat displacement system (hot water system) for flue gas cooling before the scrubber and reheating after scrubber. | |
| Scope of supply 1: | 2 flue gas coolers made entirely of steel, 1 corrosion-resistant flue gas cooler with fluoroplastic-coated steel pipes, carbon steel housing with TFM foil lining. | |
| Technische Daten: | Flue gas volume 55,000 Nm³/h Inlet/outlet temperature 280/200°C Thermal capacity 1740 KW | |
| Scope of supply 2: | 3 corrosion-resistant clean gas heaters with fluoroplastic-coated steel pipes, carbon steel housing with TFM foil lining. | |
| Technical data: | Clean gas volume 58,800 Nm³/h Inlet/outlet temperature 54/130°C Thermal capacity 1740 KW | |
| Client: | DSM Nutritional Products | |
| Receipt of order: | 08/2013 | |
| Status: | Detail engineering | |