Wallstein Holding GmbH & Co. KG

_New orders

Engineering, construction and fabrication


BIOMASSE ITALIA S.p.A. Crotone
Project description:Engineering, design and manufacturing of a flue gas cooler for a water pre-heater (economiser) consisting of 2 modules coated with fluoroplastic-coated steel pipes, casing made of carbon steel with TFM-foil lining.
Technical data:Flue gas volume 84,375 Nm³/h 
Inlet/outlet temperature 161/132 degrees C
Water volume 55.50 m³/h 
Inlet/outlet temperature 90/107 degrees C
Thermal capacity 970 KW
Client:BIOMASSE ITALIA S.P.A.
Receipt of order:11/2013
Status:Detail engineering
WtE plant Bielefeld Replacement of primary air pre-heater VL3
Project description:Engineering, design, manufacture, supply, installation and commissioning of the primary air pre-heater for incineration line 3, consisting of 2 modules with stainless steel pipes, casing with bypass, including the air-side flaps.
Technical data:Air flow 45,600 Nm³/h 
Inlet/outlet temperature 8 / approx. 124 °C
Steam 3.8 bar 
Inlet/outlet temperature 144 degrees C
Steam consumption about 3200 kg/h
Thermal output approx. 1900 KW
Client:MVA Bielefeld
Receipt of order:12/2013
Status:Detail engineering